Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog
1-18
1
LOAD CENTERS &
CIRCUIT BREAKERS
EQ
®
Load Centers
Small Circuit Load Centers
1-Phase, 3-WIre SN, 120/240Volts AC
Main Lug and Main Breaker with Copper Bus

100,000A IR
4–16 circuits, 100–225 Amperes 1-Phase, 3-Wire, SN 120/240 Volts AC
70 amp maximum breaker.
Will not accommodate 2-pole GFCI or circuit breaker with
shunt trip.
Can accommodate 2-pole GFCI breaker up to 50A. For
2-pole 60A GFCI, a restriction of #6 wire applies due to
wire bend space of the enclosure. Will not accommodate
circuit breaker with shunt trip.
100 amp maximum breaker.
Suitable for use as service entrance equipment when a main
breaker (125A maximum) is back-fed in a branch position and
used with main breaker retainer clip (Cat. No. ECMBR1).
Suitable for use as service entrance when not more than six
main disconnecting means are provided. Check local codes and
restrictions.
Two Q115 and one Q230 breaker included.
W0408L1125SPA50 provided with factory installed QF50 and
ground bar. W0408L1125SPA60 provided with factory installed
QF260 and ground bar.
Copper Bus load centers are recommended for those
applications where the environment may be severe
(i.e. farm and coastal areas).
2" HS Type hub provided.
k
Type QNR main breaker factory installed.
CSA Listed
Cover plate included
Features/Applications
EQ Load Centers with main lugs
feature a combination trim box in one
package.
Interiors offer removal in seconds
Single phase
One piece bus bar construction
designed for use only with circuit
breakers
UL Listed
UL listed on 60/75°C conductors
(see equipment markings for applica-
tions)
Positive load side circuit breaker hook
rails
Outdoor Type 3R devices use HS
Type hubs.
See page 1-21.
Main Lugs with Aluminum Bus
100,000A IR
4–16 circuits, 100–125 Amperes 1-Phase, 3-Wire, SN 120/240 Volts AC
Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R
Amp
Rating
Max.
1-Pole
No. of
Spaces
No. of
Circuits
QP
Max.
2-Poles
Catalog Number
Replace Suffix F
(Flush) with S for
Surface Mounting
Std.
Pkg.
Dimensions (inches)
Catalog
Number
Std
Pkg.
Dimensions (inches)
H W D H W D
100 12 24 6
E1224ML1100FG
1 14 3/4 12 3/8 3 7/8
125 4 8 2
E0408ML1125F

5 12 5/8 6 5/8 3 1/2
W0408ML1125

5 12 1/4 6 4 1/4
125 4 8 2
W0408L1125SPA50

1 12 1/4 6 4 1/4
125 4 8 2
W0408L1125SPA60

1 12 1/4 6 4 1/4
125 8 16 4
E0816ML1125F
1 14 3/4 12 3/8 3 7/8
Branch Circuits Indoor Enclosure — NEMA Type 1 Outdoor Enclosure — NEMA Type 3R
Amp
Rating
Max.
1-Pole
No. of
Spaces
No. of
Circuits
QP
Max.
2-Poles
Catalog
Number
Std.
Pkg.
Dimensions (inches)
Catalog
Number
Std.
Pkg.
Dimensions (inches)
H W D H W D
100 10 20 4
E1020MB1100FCGP
1 14 3/4 12 3/8 3 7/8
100 12 24 6
E1224ML1100FCU
1 14 3/4 12 3/8 3 7/8
125 8 16 4
E0816ML1125FCU
1 14 3/4 12 3/8 3 7/8
W0816ML1125CU
1 14 3/4 12 1/8 4 1/4
125 8 16 4
E0816ML1125SCU
1 14 3/4 12 3/8 3 7/8
225 4 6 2 1
W0406ML1225CU
1 23 10 4 1/8
200 4 4 2 1
W0404MB1200CT
k
1 20 11 1/8 4 3/4
150 4 4 2 1
W0404MB1150CTS
k
1 20 11 1/8 4 3/4
200 4 4 2 1
W0404MB1200CTS
k
1 20 11 1/8 4 3/4
Renovation Panel
Ideal for older home renova-
tion projects where the dis-
tance between the studs is
narrower than current
construction practices. The
narrower panel eliminates
the need to ‘notch’ out the
existing studs.
Spa Panels
Spa Panels are ideal for out-
door applications requiring
the use of ground fault pro-
tection, such as hot tubs. A
factory installed 2-Pole GFCI
breaker is provided, along
with 2 extra circuits.
Product Category RESI
Small Circuit Load
Centers
Ideal for subfeed
applications
Revised
02/26/12
Vue de la page 0
1 2 3 4 5 6 7

Résumé du contenu

Page 1 - Small Circuit Load Centers

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-181LOAD CENTERS & CIRCUIT BREAKERSEQ® Load Centers—Small Circuit Load Centers1-Phase, 3-WI

Page 2 - Circuit Breaker Enclosures

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-191LOAD CENTERS & CIRCUIT BREAKERSProduct Category RESIEQ® Load Centers—Circuit Breaker E

Page 3

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-201LOAD CENTERS & CIRCUIT BREAKERSLoad CentersLoad Center OEM Interiors  UL Recognized

Page 4

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-211LOAD CENTERS & CIRCUIT BREAKERSLoad CentersLoad Center AccessoriesCatalog Number Desc

Page 5

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-221LOAD CENTERS & CIRCUIT BREAKERSLoad CentersLoad Center Accessories Ground Bar Kit, EC2G

Page 6

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-231LOAD CENTERS & CIRCUIT BREAKERSTo activate standby power the utility main breaker must

Page 7

Siemens Industry, Inc. SPEEDFAX™ 2011 Product Catalog1-241LOAD CENTERS & CIRCUIT BREAKERSPrevents dangerous feedback between two sources of power

Commentaires sur ces manuels

Pas de commentaire